析出物信息
析出物和生物工艺产品
生物工艺必须将患者的潜在安全风险降至最低。其中包括确保有害浸出化合物不会从生产设备或储存材料进入产品。
生物工艺行业的实践使我们认识到一次性技术具有重要价值。因此,我们非常重视析出物和浸出物 (E&L) 的生产。我们的生物工艺产品经过精心设计,可最大程度降低影响药物安全性和有效性的浸出物风险。同时,我们高度重视对生物工艺产品的标准化 E&L 测试,旨在提高安全性并减少行业乱象。
我们采取的方式包括:
全面的析出物信息
我们认为,生物工艺技术制造商应负责对其组件进行析出物测试。因此,我们会提供自己产品的析出物信息。
您可以按产品分类找到可用的析出物数据,如需帮助,请参阅下面的析出物数据指南。
登录监管支持申请,即可访问相关的析出物数据以供您用于风险评估。
符合 BioPhorum 析出物方案
我们根据 BioPhorum 析出物方案测试新产品,并有序更新旧的产品。
For information in identifying and accessing available extractable studies by product type, download the Extractables Data Guide Table further below. Portal access to the reports can be found via the links in the far right column of the table. Please note two separate portals are used for sharing depending on the specific report.
Product Type | Product description | Representative part number | Primary MOC 1 | Pretreatment2 | Extractables study design | Applicable extractables reports | Report portal5 | |||
USP<665>3 | BioPhorum | Legacy4 | ||||||||
Aseptic connector | ReadyMate™ DAC | 28936688 | PC | Gamma & Autoclave | H | X | Component family file: ReadyMate DAC. Extractables study: 17-002 |
Reg. Sup. | ||
Kleenpak® sterile connector | KPCHT02F11 KPCHT02M11 |
PC | Radiation and autoclave | H | X | USTR 3946 (Comprehensive summary) | ADC | |||
Kleenpak® Presto sterile connector | PSC1G8 | PES | Radiation and autoclave | H | X | USTR 3947 (Comprehensive summary) | ADC | |||
Kleenpak® II sterile connector and disconnector | KPD01HB6 | PSU | Radiation and autoclave | H | X | VAL-AS-004126-ER1(Autoclave) VAL-AS-004126-ER2(Radiation) VAL-AS-002951-ER3 (USP, Autoclave) VAL-AS-002951-ER4 (USP, Radiation) |
ADC | |||
Bioburden control filters | Kleenpak® capsules with Supor EAV membrane | KA3EAVP1G | PES, PP, Si | Radiation and autoclave | H | X | VAL-AS-006888-ER1 (Autoclave) VAL-AS-006888-ER2 (Radiation) |
ADC | ||
Kleenpak® Nova capsules with Supor EAV membrane | NT6UEAVP1G | PES, PP | Radiation and autoclave | H | X | VAL-AS-006449-ER1 (Autoclave) VAL-AS-006449-ER2 (Radiation) |
ADC | |||
Biocontainers, mixers and bags | HyClone™ liquid media and buffer bags with CX5-14 film | N/A | Polyolefin | Gamma | M | X | Extractables study 15-004 CX5-14 film | Reg. Sup. | ||
HyClone™ liquid media and buffer bags with Cytiva Film Cell Culture 1 | N/A | Polyolefin | Gamma | H | X | Extractables study 22-031 Cytiva™ Film Cell Culture 1 | Reg. Sup. | |||
HyClone™ liquid media and buffer bags with Aegis 5-14 film | N/A | Polyolefin | Gamma | M | X | Extractables study: 15-005 Aegis5-14 film | Reg. Sup. | |||
ReadyToProcess™ bags with Fortem™ film | 29381886 | Polyolefin | Gamma | H | X | Assembly Family File: Assembly family ReadyToProcess bags with Fortem film - guide to extractables studies of components | Reg. Sup. | |||
ReadyCircuit™ bags with Fortem™ film China | 29315051 | Polyolefin | Gamma | H | X | Assembly Family File: Assembly family ReadyCircuit bags with Fortem film Extractables study: 15-003 Fortem film. Extractables study: 20-002 Fortem film in 2% Benzyl alcohol and Phosphate buffer pH 10 |
Reg. Sup. | |||
ReadyCircuit™ bags with ReadyKleer™ film | 12410225 | Polyolefin | Gamma | M | X | X | 1) Extractables study: 15-002 ReadyKleer film 2) Validation guide: VG ReadyCircuit - extractables study on Hanging bag assembly. |
Reg. Sup. | ||
WAVE Cellbag™ bioreactor and M*bag Mixing bags with Fortem™ film | CB0002L722-11-01PK | Polyolefin | Gamma | H | X | Extractables study: 15-003 Fortem film. Extractables study: 20-002 Fortem film in 2% Benzyl alcohol and Phosphate buffer pH 10. Validation guide: VG Cellbag Bioreactor bags with Fortem film |
Reg. Sup. | |||
WAVE Cellbag™ bioreactor and mixer bags with Fortem™ film China | CB0001L722-01-08PK-CN | Polyolefin | Gamma | H | X | Extractables study: 15-003 Fortem film Extractables study: 20-002 Fortem film Validation guide: VG Cellbag Bioreactor bags with Fortem film China - presents data from Extractables study 15-003 plus studies on extractable antioxidant (TBPP) and its degradation products |
Reg. Sup. | |||
WAVE Cellbag™ bioreactor and M*bag Mixing bag with Bioclear™ 11 film | CB0002L11-01 | EVA | Gamma | M | X | X | 1) Extractables study: 15-006 Bioclear 11 film 2) Validation guide: VG Cellbag bioreactor and Mbag mixing bag with Bioclear 11 film - presents study on Cellbag assembly/td> |
Reg. Sup. | ||
WAVE Cellbag™ bioreactor and M*bag mixing bags with Bioclear™ 10 film | CB0002L10-01 | EVA | Gamma | X | Validation guide: VG Cellbag bioreactor and M*bag mixing bag with Bioclear 10 film - presents studies on Cellbag assemblies | Reg. Sup. | ||||
Xcellerex™ XDM bags with Fortem™ film | 29300460 | Polyolefin | Gamma | H | X | Assembly Family File: Assembly family XDM bags with Fortem film - guide to extractables studies of components | Reg. Sup. | |||
Xcellerex™ XDM bags with ASI 26/77 film | 888-0086-N | Polyolefin | Gamma | M | X | X | 1) Extractables study: 15-001 ASI 26/77 film 2) Validation guide: VG Xcellerex XDA disposable assemblies - extractables study on PEEK impeller and listing of surface areas of bag film and impellers |
Reg. Sup. | ||
Xcellerex™ XDR bags with ASI 26/77 film | 888-0070-C | Polyolefin | Gamma | M | X | X | 1) Extractables study: 15-001 ASI 26/77 film 2) Validation guide: VG Xcellerex XDA disposable assemblies - extractables studies on PEEK impeller and polycarbonate material, with surface areas of bag film and impellers |
Reg. Sup. | ||
Xcellerex™ XDR perfusion bags with ASI 26/77 film | 29605397 | Polyolefin | Gamma | M | X | Assembly Family File: Assembly family Bioreactor bags for Xcellerex APS - guide to extractables studies of components. | Reg. Sup. | |||
Xcellerex™ XDR- bags with ReadyKleer™ film | 29398286 | Polyolefin | Gamma | M | X | Asselby Family File: Assembly family XDR bags with ReadyKleer film 2) Validation guide: VG XDA disposable assemblies - extractables study on PEEK impeller and listing of surface areas of bag film and impellers |
Reg. Sup. | |||
Xcellerex™ X-platform bioceactor bags | 29696534 | Polyolefin | Gamma | M | X | Assembly Family File: Assembly family Xcellerex X-platform bioreactor bags | Reg. Sup. | |||
Assembly family XDR-2000L Pro Max Bag | 29724937 | Polyolefin | Gamma | M | X | Assembly Family File: Assembly family XDR-2000L Pro Max Bag - guide to extractables studies of components. | Reg. Sup. | |||
Allegro™ 2D and 3D biocontainer chambers (film, port) | LGR0010L7700 (619-31A) |
ULDPE, HDPE | Radiation | H | X | USTR 3941 | ADC | |||
Magnetic mixer impeller | 4100654 | HDPE, PVDF, ceramic | Radiation | H | X | VAL-AS-006929-ER1 | ADC | |||
Allegro single-use mixers | Various | Various | Radiation | X | USTR 2777a | ADC | ||||
LevMixeer & Magnetic Mixers | LGRLMC0050L0001 | ULDPE, HDPE | N/A | USTR 3983 (Materials, Surface Areas, and Applicable Extractables Reports) | ADC | |||||
Column housing | AxiChrom™ 50 to 200 columns | 29016534 | Glass | Cleaning in place (CIP) | X | Extractables study: 15-015 AxiChrom 50 to 200 columns | Reg. Sup. | |||
AxiChrom™ 300 to 1600 columns | 29457805 | Polymethyl methacrylate (PMMA) | CIP | X | Extractables study: 15-014 AxiChrom 300 to 1600 columns | Reg. Sup. | ||||
BPG columns | 18110301 | Glass | CIP | X | Extractables study: 15-017 BPG columns | Reg. Sup. | ||||
Chromaflow™ columns | 18116141 | PMMA | CIP | X | Extractables study: 15-016 Chromaflow columns | Reg. Sup. | ||||
ReadyToProcess™ column housings ≤359 mm | N/A | Polyolefin | N/A | M | X | Validation guide: VG ReadyToProcess columns | Reg. Sup. | |||
ReadyToProcess™ column housings ≥450 mm | N/A | PMMA | N/A | M | X | Validation guide: VG ReadyToProcess columns | Reg. Sup. | |||
Filling needles | Allegro™ single-use filling needle | DFNST1208632 | PEEK | Radiation and autoclave | H | X | VAL-AS-008892-ER1 (Autoclave) VAL-AS-008892-ER2 (Radiation) |
ADC | ||
Allegro™ single-use filling needle | DFNLR1208632 | PEEK, PP | Radiation and autoclave | X | USTR 2837a | ADC | ||||
Fittings | Polypropylene fittings | FY02311 | PP | Radiation | M | VAL-AS-011234-ER | ADC | |||
Large-scale drain valve (O-ring) | SC00817 (O-ring) | SI | Radiation | X | VAL-AS-005734-ER | ADC | ||||
Large-scale drain valve (spigot) | SC00816, SC00817 | PBT | Radiation | M | X | VAL-AS-007006-ER1 | ADC | |||
Hardware system | ÄKTA™ Pilot 600 | 29274328 | Fluorinated Ethylene Propylene (FEP) | CIP | M | X | Extractables study: 17-001 ÄKTA pilot 600 | Reg. Sup. | ||
ÄKTA process™ | N/A | Polyolefin | CIP | H | X | X | 1) Extractables study: 15-019 ÄKTAprocess PP system 2) Extractables study: 22-001 ÄKTA process |
Reg. Sup. | ||
UniFlux™ 30 | 29001375 | Stainless steel | CIP | X | Extractables study: 15-020 UniFlux 30 | Reg. Sup. | ||||
Process filters | Profile® II Filter cartridges | AB1Y0057PH4 | PP, PE, Si | Radiation and autoclave | M | VAL-AS-009605-ER10 (Autoclave) VAL-AS-009605-ER11 (Radiation) |
ADC | |||
Duo-Fine® II series filter | DFNT04510USM7 | Fiberglass, PP, PE, Si | Autoclave | M | PHA-AM-014106-ER3 | ADC | ||||
ULTA™ Prime GF | 28908433 | Glass microfiber | Autoclave | X | Extractables study: 15-023 ULTA Prime GF | Reg. Sup. | ||||
ULTA™ Prime PP | 28908477 | Polyolefin | Autoclave | X | Extractables study: 15-024 ULTA Prime PP | Reg. Sup. | ||||
ReadyToProcess™ ULTA™ filter capsules | 29410059 | Polyethersulfone | Gamma | X | Validation guide: VG ReadyCircuit - extractables studies on ReadyToProcess ULTA HC; ULTA SG; ULTA CG; ULTA GF assemblies | Reg. Sup. | ||||
Sensors | Broadley James® single-use pH sensor | SU-800-1100-N | PEEK, EPDM, Si | Radiation | H | VAL-AS-010802-ER | ADC | |||
Broadley James® single-use bioprocessing container (BPC) gas wells | SU-100 | PEEK, PPSU, Si | Radiation | M | VAL-AS-013144-ER | ADC | ||||
Sterilizing grade filters | Kleenpak® capsules with Supor® EKV membrane | KA3EKVP1G | PES, PP | Radiation and autoclave | H | X | USTR 3948 (Comprehensive summary) | ADC | ||
Kleenpak® Nova capsules with Supor® EKV membrane | NT6EKVP1G | PES, PP | Radiation and autoclave | M | X | VAL-AS-005068-ER1 (Autoclave) VAL-AS-005068-ER2 (Radiation) |
ADC | |||
Kleenpak® Nova capsules with Supor® EX grade ECV membrane | NP6UECVP1G | PES, PP, Si | Radiation and autoclave | H | X | USTR 3949 (Comprehensive summary) | ADC | |||
Kleenpak® Nova capsules with Fluorodyne® EX grade EDF membrane | NT6UEDFP1G | PES, PVDF, PP, Si | Radiation and autoclave | H | X | USTR 3950 (Comprehensive summary) | ADC | |||
Kleenpak® Nova capsules with Fluorodyne® EX grade EDT membrane | NT6UEDTP1G | PES, PVDF, PP, Si | Radiation and autoclave | H | X | USTR 3951 (Comprehensive summary) | ADC | |||
Supor Prime Filter in Kleenpak® Spectrum Capsule and Cartridge Format | FC6ASFP1 | PES, PP | Radiation and autoclave | H | X | VAL-AS-012571-ER1 (Autoclave) VAL-AS-012571-ER2 (Radiation) |
ADC | |||
Kleenpak® Nova capsules with Fluorodyne II DFL membrane | NT6DFLP1G | PVDF, PP, Si | Radiation and autoclave | H | X | VAL-AS-005884-ER1 (Autoclave) VAL-AS-005884-ER2 (Radiation) VAL-AS-005884-ER2 (Radiation, 1% PS80) |
ADC | |||
Kleenpak® capsules with Fluorodyne II DFL membrane | KA3DFLP1G | PVDF, PP | Radiation and autoclave | H | X | VAL-AS-002700-ER1 (01) (Autoclave) VAL-AS-002700-ER2 (01) (Radiation) VAL-AS-009149-ER1 (USP, Autoclave) VAL-AS-009149-ER2 (USP, Radiation) |
ADC | |||
Polypropylene filter hardware used in Pall NP5L Kleenpak® Nova capsules and AB05 filter cartridges | FY00631, FY00630, FY00111 | PP | Radiation and autoclave | H | X | VAL-AS-009305-ER1 (Autoclave) VAL-AS-009305-ER2 (Radiation) |
ADC | |||
Kleenpak® Nova capsules with Posidyne® membrane | NT6NFZP1G | Nylon, PP, PE, Si | Autoclave | H | X | VAL-AS-008626-ER1 | ADC | |||
Ultipor® N66 filter cartridges | AB1NF7P | PP, Nylon | Autoclave | M | X | PHA-AM-009775-1 | ADC | |||
Emflon® II filter cartridges | AB1V0027PV | PVDF, PP | Autoclave | M | X | PHA-EU-000990-1 (Water) PHA-EU-000990-4 (50% Ethanol) |
ADC | |||
Kleenpak® capsules with Emflon II membrane | KA3V002PV1G | PVDF, PP, EPDM | Gamma | M | X | PHA-EU-013161-ER | ADC | |||
Tangitial flow filters (TFF) | Cadence® single-use TFF modules with Omega™ PES membrane | CSUM010T050, CSUM010T010 |
PES, PSU, PP | N/A | X | USTR 2906 (Water) USTR 2928 (25% Ethanol) |
ADC | |||
T-Series TFF cassettes with Omega membrane | OS030T06 | PES, urethane, PP | N/A | X | TR451402732 | ADC | ||||
Cadence inline diafiltration module with Omega PES membrane | DFOS030T120612 | PES, PP, Si, PSU | N/A | X | PHA-AM-013313-ER1 | ADC | ||||
Cadence inline diafiltration module with Delta regenerated cellulose membrane | DFDC030T120612 | Reg. cellulose, PP, Si | N/A | X | PHA-AM-013313-ER3 | ADC | ||||
ReadyToProcess Microfiltration hollow fiber filter | RTPCFP-2-E-6S | Polysulfone | Gamma | X | Validation guide: VG ReadyToProcess hollow fiber cartridges. | Reg. Sup. | ||||
ReadyToProcess Ultrafiltration hollow fiber filter | RTPUFP-30-C-6S RTPUFP-750-E-6S |
Polysulfone | Gamma | X | Validation guide: VG ReadyToProcess hollow fiber cartridges | Reg. Sup. | ||||
Microfiltration hollow fiber filter | CFP-2-E-6A CFP-2-E-35STM |
Polysulfone | CIP / Steam in place (SIP) | X | 1) Extractables study: 15-021 Hollow fiber cartridges | Reg. Sup. | ||||
Ultrafiltration hollow fiber filter | UFP-10-C-6A UFP-100-E-6A UFP-10-E-35 UFP-10-C-55STM UFP-10-E-55STM |
Polysulfone | CIP / SIP | H | X | X | 1) Extractables study: 15-021 Hollow fiber cartridges 2) Extractables study: 18-019 Hollow fiber ultrafiltration cartridges |
Reg. Sup. | ||
Filling flow kits | Single-Use Needle and Flow Path with DAC | 610477, 600460 | Silicone | Gamma | M | X | X | Assembly Family File: Assembly family information Single-Use Needle (SUN) and Flow Path with DAC | Reg. Sup. | |
Allegro™ Connect Bulk Fill system | ACBFSCEPLC ACBFSCEIO ACBFSULIO ACBFSULPLC |
Slicone, PP, PSE, PES | Radiation | H | X | VAL-AS-014453-ER | ADC | |||
ÄKTA ready™ Flow Kit | 28930182 | Silicone | Gamma | H | X | Validation guide: VG ÄKTA ready Flow Kit | Reg. Sup. | |||
ÄKTA ready™ XL Flow Kit | 29264593 | Silicone | Gamma | M | X | Validation guide: VG ÄKTA ready XL Flow Kit | Reg. Sup. | |||
ÄKTA readyflux™ Flow Kit | 29187383 | Thermoplastic elastomer (TPE) | Gamma | H | X | Validation guide: VG ÄKTA readyflux Flow Kit | Reg. Sup. | |||
ÄKTA readyflux™ XL Flow Kit | 29403132 S | Silicone | Gamma | M | X | Assembly Family File: Assembly family ÄKTA readyflux XL flow kit - guide to extractables studies of components | Reg. Sup. | |||
ÄKTA ready™ 450 Flow Kit | 29631244 | Silicone | Gamma | M | X | Assembly Family File: Assembly family ÄKTA ready 450 flow kit - guide to extractables studies of components | Reg. Sup. | |||
Tubing kit for AxiChrom™ 200 | 28943020 | Silicone | N/A | X | Extractables study: 15-027 Silicone Tubing Kit for AxiChrom 200 | Reg. Sup. | ||||
Tubing kit for chromatography hardware | 28938126 | Polytetrafluoroethylene (PTFE) | N/A | X | Extractables study: 15-028 Tubing PTFE | Reg. Sup. | ||||
Xcellerex™ APS flow kit | 29377111 | TPE | Gamma | H | X | 1) Assembly family file: Xcellerex APS flow kit - guide to extractables studies of components. 2) Extractables study: 19-002 Xcellerex APS flow kit. | Reg. Sup. | |||
Virus filters | Kleenpak Nova capsules with Pegasus™ Prime virus removal filter membrane | NP6LUPRMP1S | PES, PP | Radiation and autoclave | H | X | VAL-AS-004360-ER (Radiation) VAL-AS-004360-ER1 (Autoclave) |
ADC | ||
Kleenpak Nova capsules with Pegasus™ SV4 virus removal filter membrane | NT6USV4P1 | PVDF, PE, PP, Si | Autoclave | H | X | VAL-AS-008472-ER1 | ADC | |||
Kleenpak Nova capsules with Pegasus™ Protect virus prefilter membrane | NP6PRTP1 | Nylon, PP, PE | Autoclave | H | X | VAL-AS-005331-ER1 | ADC | |||
Kleenpak Nova capsules with Pegasus™ Protect virus prefilter membrane | NP6LPRTP1G | Nylon, PP, PE | Gamma | H | X | VAL-AS-005331-ER2 | ADC | |||
Note 1: Materials of construction: ULDPE = Ultra-low density polyethylene; HDPE = High-density polyethylene; EVA= Ethylenevinylacetate; PC = Polycarbonate; PSU = Polysulfone; PES = Polyethersulfone; PP = Polypropylene; PVDF = Polyvinylidene fluoride; PEEK = Polyether ether ketone; Si = Silicone elastomer; PBT = Polybutylene terephthalate; EPDM = Ethylene propylene diene monomer; PPSU = Polyphenylsulfone. Note 2: Radiation refers to X-ray and/or Gamma irradiation. Note 3: USP<665> is divided into High (H) or Moderate (M) risk level study design. Only fully satisfied USP <665> high risk dataset would be marked H, otherwise M. Note 4: Dataset available using different study design than USP<665> or BPOG. Note 5: See description on top how to access the portal. Note 6: Summary of extractable studies and other relevant information supporting risk assessment with all report files embedded |
Updated: June 2024
How to access the data:
i. Navigate to cytiva.com/rsf
ii. Choose either Access Regulatory Support (Reg. Sup.) or the Accelerator Documentation Center (ADC) as noted in the Report portal column below.
iii. Log in to the portal. A confidentiality agreement will need to be accepted and approved before access to reports is provided.
Document USTR 3437 is now part of this data guide